Y6 Premium Medium Bodied Low VOC ABS

Y6 Premium Medium Bodied Low VOC ABS

product

Product Description and Uses:

Schwartz Premium ABS Cement is used for bonding ABS to ABS pipes for Non-Pressure applications such as DWV and pipe fittings.

Certification:

CSA certified for ABS non-pressure applications.
Canada Green Building Council - Leed Compliant.

IPS Part # Container Description Model # Case Qty CA Size US Size
19048 Plastic, Dauber Y6DS 118 24 118 ml 1/4 Pt
19049 Plastic, Dauber Y6DS 236 24 236 ml 1/2 Pt
19050 Plastic, Dauber Y6DS 473 12 473 ml Pint
19051 Plastic, Dauber Y6DS 946 12 946 ml Quart
19047 Plastic, Screw Top no Dauber Y6 004 4 3.78 L Gallon
Physical Properties:  
Density: 0.85 – 0.89 g/ml
Weight Solids: 21 - 31%
Flashpoint: - 8.9°C
Viscosity: 400 - 600 cps Brookfield LV
Lap Shear: 800 psi (5.5MPa) at 48 hrs per ASTM D 2235
Appearance: Yellow liquid
Shelf Life: 3 years unopened
Suggested Uses: For ABS to ABS non-pressure applications such as drain, waste and vent pipes and fittings.
Application Tools: Dauber or brush.
Clean-up Solvent: VC100
Pot Life: NA

Material Safety and Technical Data Sheets for Download

TDS

TDS 38Y6 -Y6 Premium Medium Bodied Low VOC ABS Solvent Cement (pdf)

SDS

SDS 38Y6 -Y6 Premium Medium Bodied Low VOC ABS Solvent Cement (pdf)
SDS 38Y6 - Colle à solvant à faible teneur en COV Y6 ABS - 38Y6 (pdf - French)

Set Times:

Handle newly assembled joints carefully until cement has gone through its set period.

Recommended set time is temperature dependent:
- Minimum 30 minutes at 15ºC to 38ºC
- Minimum 1 hour at 7ºC to 15ºC
- Minimum 2 hours at 0ºC to 4ºC

Cure Times:
  Test Pressures For Pipe Sizes 1⁄2" to 1-1⁄4" Test Pressures For Pipe Sizes 1-1⁄2" to 3" Test Pressures For Pipe Sizes 3-1⁄2" to 8"
Temperature Range During Cure Period Up to 180 psi Above 180 to 370 psi Up To 180 psi Above 180 To 315 psi Up To 180 psi Above 180 To 315 psi
15°C - 38°C 1 hr. 6 hr 2 hr. 12 hr. 8 hr. 24 hr.
4°C - 15°C 2 hr. 12 hr. 4 hr. 24 hr. 16 hr. 48 hr.

Storage:

Store indoor at room temperature, away from heat, ignition sources, open flames and direct sunlight.

Warning:

Avoid open flames, turn off all pilot lights, ensure that work area is properly ventilated.

Soiled rags and waste products may contain combustible liquids or vapours and SPONTANEOUSLY COMBUST, dispose in accordance with local regulations.

Refer to SDS for information on safe use of this product.

Plumbing Product Selector Table

Plumbing Product Selector Table

Don't see the cement you need? Call Customer Service at 800-888-8312.

 
Site Map  |  Careers  |  Industry Links  |  Limited Warranty  |  IPS Canada  |  About IPS Corporation