Multi-Size Pneumatic Test Plugs

Features

  • Designed for the testing of pipelines or to temporarily stop the flow
  • Each plug is designed for two or more pipe sizes
  • Plugs are suitable for many different pipe materials
  • Manufactured from a durable natural rubber compound
  • 4-8" through 12-24" sizes come with a replaceable pressure relief valve
  • 1 1/4"-2" through 3-4" sizes come with a 1/4" NPT Replaceable Inflation Valve
  • Contains an eyebolt for tethering
  • Replaceable tank valve can be changed to a quick disconnect plug for faster inflation
  • California Residents: WARNING – www.P65warnings.ca.gov
Nominal Size Product Code Pipe Use Range Plug Diameter (inches) Plug Length (inches) Overall Plug Length (inches) Bypass Size (inches) Inflation Pressure (psig) Maximum Back Pressure Units/
Case
Minimum Pipe Diameter (inches) Maximum Pipe Diameter (inches) Water Head (feet) Air (psig)
1 1/4-2″ 83212 1.18 2.25 1.13 3.00 4.50 None 40 30 13 6
2-3″ 83225 1.85 2.60 1.75 3.00 4.50 None 40 30 13 6
3-4″ 83234 2.63 4.25 2.50 3.88 5.50 None 35 30 13 6
4-6″ 83246 3.41 6.25 3.25 5.75 7.25 None 30 30 13 1
4-8″ 83248 3.70 8.25 3.50 10.00 12.00 None 30 30 13 1
6-8″ 83268 5.51 8.25 5.25 10.00 12.00 None 30 40 17 1
6-10″ 83261 5.39 10.25 5.13 12.00 14.00 None 30 40 17 1
8-12″ 83282 7.09 12.25 6.75 15.75 17.50 None 30 40 17 1
10-16″ 83216 8.92 16.25 8.50 17.13 19.13 None 30 40 17 1
12-18″ 83218 11.02 18.25 10.50 23.00 25.00 None 30 40 17 1
12-24″ 83633 11.95 24.25 11.50 28.75 31.00 None 30 12 5 1

 

Multi-Size Pneumatic Test Plugs – Bulk Pack

Nominal Size Product Code Pipe Use Range Plug Diameter (inches) Plug Length (inches) Overall Plug Length (inches) Bypass Size (inches) Inflation Pressure (psig) Maximum Back Pressure Units/
Case
Minimum Pipe Diameter (inches) Maximum Pipe Diameter (inches) Water Head (feet) Air (psig)
1 1/4″ – 2″ 83112 1.18 1.75 1.13 3.75 5.25 None 40 30 13 12
3-4″ 83114 2.63 4.25 2.50 3.88 5.50 None 35 30 13 12

Don’t see the product you need? Call Customer Service at 800-888-8312.